| LEADER |
02532na a2200229 4500 |
| 003 |
HR-ZaFER |
| 008 |
160221s2017 ci ||||| m||| 00| 0 hr d |
| 035 |
|
|
|a (HR-ZaFER)ferid4787
|
| 040 |
|
|
|a HR-ZaFER
|b hrv
|c HR-ZaFER
|e ppiak
|
| 100 |
1 |
|
|a Đurđević, Luka
|
| 245 |
1 |
0 |
|a Sustav za nadzor prekomjerne potrošnje električne energije :
|b diplomski rad /
|c Luka Đurđević ; [mentor Mario Vražić].
|
| 246 |
1 |
|
|a Excessive power consumption control system
|i Naslov na engleskom:
|
| 260 |
|
|
|a Zagreb,
|b L. Đurđević,
|c 2017.
|
| 300 |
|
|
|a 41 str. ;
|c 30 cm +
|e CD-ROM
|
| 502 |
|
|
|b diplomski studij
|c Fakultet elektrotehnike i računarstva u Zagrebu
|g smjer: Elektrotehnički sustavi i tehnologija, šifra smjera: 50, datum predaje: 2017-06-29, datum završetka: 2017-07-07
|
| 520 |
3 |
|
|a Sažetak na hrvatskom: U sklopu diplomskog rada izrađena je programska podrška sustava za nadzor prekomjerne potrošnje električne energije. Programska podrška omogućuje nadzor i arhiviranje trenutne snage te detekciju prekoračenja zakupljene snage u intervalima od 15 minuta. U slučaju prekoračenja zakupljene snage za interval u kojem je nastupilo prekoračenje arhiviraju se maksimalne vrijednosti snage i parametri transformatora za trenutak maksimalne snage. Programska podrška sustava sastoji se od programske podrške PLC-a, operatorskog panela i SCADA sustava.
Programska podrška izrađena je tako da bude kompatibilna s PLC-om serije S7-300 i rađena je u programskom alatu TIA Portal V13 SP1.
|
| 520 |
3 |
|
|a Sažetak na engleskom: As part of the graduate thesis, a software program for the excessive consumption of electricity was developed. This programe support enable monitoring and archiving FER’s current power and detects moments of exceeded power over interval of 15 minutes. In case of exceeding the leased power for the interval in which the exceeding occurs, the maximum power values and transformer parameters are archived for a moment of maximum power. The program support of the system is consisted of PLC, HMI and SCADA system support. The software support was designed to be compatible with the PLC S7-300 and was developed in the TIA Portal V13 SP1 software.
|
| 653 |
|
1 |
|a PLC S7 300
|a SCADA
|a HMI
|a arhiva ukupne snage sustava
|a prekoračenje zakupljene snage, trenutna snaga
|a nadzor trenutne i maksimalne snage
|
| 653 |
|
1 |
|a PLC S7 300
|a SCADA
|a HMI
|a archive of total power
|a exceed of the leased power
|a current power
|a monitoring of current and maximu power
|
| 700 |
1 |
|
|a Vražić, Mario
|4 ths
|
| 942 |
|
|
|c Y
|
| 999 |
|
|
|c 48520
|d 48520
|