| LEADER |
02733na a2200241 4500 |
| 003 |
HR-ZaFER |
| 005 |
20160516012021.0 |
| 008 |
160221s2014 ci ||||| m||| 00| 0 hr d |
| 035 |
|
|
|a (HR-ZaFER)ferid1588
|
| 040 |
|
|
|a HR-ZaFER
|b hrv
|c HR-ZaFER
|e ppiak
|
| 100 |
1 |
|
|a Milović, Siniša
|9 35200
|
| 245 |
|
|
|a Sustav za nadzor potrošnje i kvalitete električne energije :
|b diplomski rad /
|c Siniša Milović ; [mentor Mario Vražić].
|
| 246 |
1 |
|
|a System for monitoring of electric energy consumption and quality
|i Naslov na engleskom:
|
| 260 |
|
|
|a Zagreb,
|b S. Milović,
|c 2014.
|
| 300 |
|
|
|a 37 str. ;
|c 30 cm +
|e CD-ROM
|
| 502 |
|
|
|b diplomski studij
|c Fakultet elektrotehnike i računarstva u Zagrebu
|g smjer: Elektrotehnički sustavi i tehnologija, šifra smjera: 50, datum predaje: 2014-06-30, datum završetka: 2014-07-07
|
| 520 |
3 |
|
|a Sažetak na hrvatskom: Cilj ovog rada bio je prikupiti, pohraniti i prikazati izmjerene podatke s trofaznih multimetra ugrađenih u katne razvodne ormare u C zgradi FER-a.
U prvom dijelu rada su opisane tehničke specifikacije multimetara i RS485/Ethernet pretvornika, njihov raspored u sustavu, komunikacijski protokoli koje ti uređaji podržavaju te postavljanje konfiguracije uređaja. U drugom dijelu rada su opisane korištene programske tehnologije, konfiguracija OPC servera, izrada baze podataka i funkcionalnost aplikacije za vizualizaciju izmjerenih podataka.
Aplikacija daje dnevni grafički prikaz radne i jalove snage, te tablični prikaz trenutnih vrijednosti veličina karakterističnih električnoj energiji.
|
| 520 |
3 |
|
|a Sažetak na engleskom: The main objective of this thesis was to collect, store, and present data measured by three-phase multimeters, embedded into distribution boards located on each floor of the C building, at Faculty of Electrical Engineering and Computing, University of Zagreb.
The first part of the thesis describes technical specifications of multimeters and RS485/Ethernet converter, their placement within the system, communication protocols supported by these devices, and their configuration setup. The second part of the thesis presents used software technologies, configuration of the OPC server, build-up of the database, and functionality of the application for visualization of measured data.
Application presents daily graphical display of active and reactive power, so as tabulation of actual variable values describing electrical energy.
|
| 653 |
|
1 |
|a nadzor potrošnje
|a multimetar
|a pretvornik
|a komunikacijski protokol
|a OPC server
|a prikaz podataka
|
| 653 |
|
1 |
|a consumption monitoring
|a multimeter
|a converter
|a communication protocol
|a OPC server
|a data representation
|
| 700 |
1 |
|
|a Vražić, Mario
|4 ths
|9 18260
|
| 942 |
|
|
|c Y
|2 udc
|
| 999 |
|
|
|c 45530
|d 45530
|