The influence of various optimization algorithms on nuclear power plant steam turbine exergy efficiency and destruction

This paper presents an exergy analysis of the whole turbine, turbine cylinders and cylinder parts in four different operating regimes. Analyzed turbine operates in nuclear power plant while three of four operating regimes are obtained by using optimization algorithms – SA (Simplex Algorithm), GA (Ge...

Full description

Permalink: http://skupnikatalog.nsk.hr/Record/nsk.NSK01001131334/Details
Matična publikacija: Pomorstvo (Online)
35 (2021), 1 ; str. 69-86
Glavni autori: Mrzljak, Vedran (Author), Anđelić, Nikola, inženjer strojarstva, Lorencin, Ivan, Baressi Šegota, Sandi
Vrsta građe: e-članak
Jezik: eng
Predmet:
Online pristup: https://doi.org/10.31217/p.35.1.8
Hrčak
LEADER 02840naa a22003614i 4500
001 NSK01001131334
003 HR-ZaNSK
005 20220509143743.0
006 m d
007 cr||||||||||||
008 220314s2021 ci d |o |0|| ||eng
024 7 |2 doi  |a 10.31217/p.35.1.8 
035 |a (HR-ZaNSK)001131334 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
042 |a croatica 
044 |a ci  |c hr 
080 1 |a 621  |2 2011 
100 1 |a Mrzljak, Vedran  |4 aut 
245 1 4 |a The influence of various optimization algorithms on nuclear power plant steam turbine exergy efficiency and destruction  |h [Elektronička građa] /  |c Vedran Mrzljak, Nikola Anđelić, Ivan Lorencin, Sandi Baressi Šegota. 
300 |b Graf. prikazi. 
504 |a Bibliografija: 109 jed. 
504 |a Summary. 
520 |a This paper presents an exergy analysis of the whole turbine, turbine cylinders and cylinder parts in four different operating regimes. Analyzed turbine operates in nuclear power plant while three of four operating regimes are obtained by using optimization algorithms – SA (Simplex Algorithm), GA (Genetic Algorithm) and IGSA (Improved Genetic-Simplex Algorithm). IGSA operating regime gives the highest developed mechanical power of the whole turbine equal to 1022.48 MW, followed by GA (1020.06 MW) and SA (1017.16 MW), while in Original operating regime whole turbine develop mechanical power equal to 996.29 MW. In addition, IGSA causes the highest increase in developed mechanical power of almost all cylinders and cylinder parts in comparison to the Original operating regime. All observed optimization algorithms increases the exergy destruction of the whole turbine in comparison to Original operating regime - the lowest increase causes IGSA, followed by GA and finally SA. The highest exergy efficiency of the whole turbine, equal to 85.92% is obtained by IGSA, followed by GA (85.89%) and SA (85.82%), while the lowest exergy efficiency is obtained in Original operating regime (85.70%). Analyzed turbine, which operates by using wet steam is low influenced by the ambient temperature change. IGSA, which shows dominant performance in exergy analysis parameters of the analyzed turbine, in certain situations is overpowered by GA. Therefore, in optimization of steam turbine performance, IGSA and GA can be recommended. 
653 0 |a Nuklearne elektrane  |a Parne turbine  |a Eksergija  |a Optimizacijski algoritmi 
700 1 |a Anđelić, Nikola,  |c inženjer strojarstva  |4 aut 
700 1 |a Lorencin, Ivan  |4 aut 
700 1 |a Baressi Šegota, Sandi  |4 aut 
773 0 |t Pomorstvo (Online)  |x 1846-8438  |g 35 (2021), 1 ; str. 69-86  |w nsk.(HR-ZaNSK)000663208 
981 |b Be2021  |b B02/21 
998 |b dalo2205 
856 4 0 |u https://doi.org/10.31217/p.35.1.8 
856 4 0 |u https://hrcak.srce.hr/259315  |y Hrčak 
856 4 1 |y Digitalna.nsk.hr