Comparation of the analytical and experimental models of 304SS corrosion rate in 0.5 m H2SS4 with bee wax propolis extract

Corrosion in the reservoir and transport vessel often causes a leak that leads to disaster. Data prediction and experimental corrosion in storage technology is very important to prevent damage and reduce maintenance costs. Theoretically, steel tank corrosion by sulfuric acid working medium can be mi...

Full description

Permalink: http://skupnikatalog.nsk.hr/Record/nsk.NSK01001046211/Details
Matična publikacija: Engineering review (Online)
38 (2018), 2 ; str. 182-188
Glavni autori: Suprapto, Wahyono (Author), Soenoko, Rudy, Gapsari, Femina
Vrsta građe: e-članak
Jezik: eng
Predmet:
Online pristup: https://doi.org/10.30765/er.38.2.6
Hrčak
LEADER 02292naa a22003614i 4500
001 NSK01001046211
003 HR-ZaNSK
005 20191121114304.0
006 m d
007 cr||||||||||||
008 191108s2018 ci a |o |0|| ||eng
024 7 |2 doi  |a 10.30765/er.38.2.6 
035 |a (HR-ZaNSK)001046211 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
041 0 |a eng  |b eng 
042 |a croatica 
044 |a ci  |c hr 
080 1 |a 620  |2 2011 
100 1 |a Suprapto, Wahyono  |4 aut  |9 HR-ZaNSK 
245 1 0 |a Comparation of the analytical and experimental models of 304SS corrosion rate in 0.5 m H2SS4 with bee wax propolis extract  |h [Elektronička građa] /  |c Wahyono Suprapto, Rudy Soenoko, Femina Gapsari. 
300 |b Ilustr. 
504 |a Bibliografija: 25 jed. 
504 |a Abstract. 
520 |a Corrosion in the reservoir and transport vessel often causes a leak that leads to disaster. Data prediction and experimental corrosion in storage technology is very important to prevent damage and reduce maintenance costs. Theoretically, steel tank corrosion by sulfuric acid working medium can be minimized with the formation of sediments oxide by oxidation-reduction reaction. Behavioral inhibition of bee wax propolis on the 304SS in 0.5 M sulfuric acid was carried by potentiodynamic polarization. Based on the polarization testing the corrosion rate of the 304SS in a solution of 0.5 M H2SO4 is at 0.349 g/m2d with the missing mass amounted 5.21 x10 -9 g/s. In experiments, the inhibitor causing less mass loss is equal to 2.28 x 10 -11 g/s. Mass lost without and with inhibitor in this study is also known by theoretical calculations. The mass losses can be used to determine the inhibition efficiency. The calculation of the efficiency theoretically and experimentally gives the same result. 
653 0 |a Transportni brodovi  |a Korozija  |a Zaštita od korozije  |a Polarizacija  |a Inhibicija korozije 
700 1 |a Soenoko, Rudy  |4 aut  |9 HR-ZaNSK 
700 1 |a Gapsari, Femina  |4 aut  |9 HR-ZaNSK 
773 0 |t Engineering review (Online)  |x 1849-0433  |g 38 (2018), 2 ; str. 182-188  |w nsk.(HR-ZaNSK)000848891 
981 |b Be2018  |b B02/18 
998 |b tino1911 
856 4 0 |u https://doi.org/10.30765/er.38.2.6 
856 4 1 |y Digitalna.nsk.hr 
856 4 0 |u https://hrcak.srce.hr/196256  |y Hrčak