Spectrophotometric determination of the dissociation constants of fluorescein in micellar media

Summary: The investigation of the dissociation equilibrium of fluorescein in aqueous micellar solution was determined spectrophotometrically at 25 °C and at ionic strength of 0.1 mol dm−3. For this purpose, the effect of nonionic (TX100), cationic (CTAB) and anionic (SDS) surfactants on the absorpti...

Full description

Permalink: http://skupnikatalog.nsk.hr/Record/nsk.NSK01000735407/Details
Matična publikacija: Croatica chemica acta
82 (2009), 4 ; str. 753-759
Glavni autor: Niazi, Ali, kemičar (-)
Ostali autori: Yazdanipour, Ateesa (-), Ghasemi, Jahanbakhsh, Kubista, Mikael, Sheyda, Azemat, Alikhah, Mahtab
Vrsta građe: Članak
Jezik: eng
Predmet:
Online pristup: Croatica Chemica Acta
LEADER 02227caa a2200325 ir4500
001 NSK01000735407
003 HR-ZaNSK
005 20130307104833.0
007 ta
008 100503s2009 ci ||| ||eng
035 |9 (HR-ZaNSK)738030 
035 |a (HR-ZaNSK)000735407 
040 |a HR-ZaNSK  |b hrv  |c HR-ZaNSK  |e ppiak 
042 |a croatica 
080 |a 54  |2 MRF 1998. 
100 1 |a Niazi, Ali,  |c kemičar 
245 1 0 |a Spectrophotometric determination of the dissociation constants of fluorescein in micellar media /  |c Ali Niazi, Ateesa Yazdanipour, Jahanbakhsh Ghasemi, Mikael Kubista, Azemat Sheyda, and Mahtab Alikhah. 
300 |b Ilustr. 
504 |a Bibliografija: 48 jed 
520 8 |a Summary: The investigation of the dissociation equilibrium of fluorescein in aqueous micellar solution was determined spectrophotometrically at 25 °C and at ionic strength of 0.1 mol dm−3. For this purpose, the effect of nonionic (TX100), cationic (CTAB) and anionic (SDS) surfactants on the absorption spectra of fluorescein at different pH values were studied. To evaluate the pH-absorbance data, a resolution based on the combination of soft- and hard-modeling is applied. The acidity constants of all related equilibria are estimated using the whole spectral fitting of the collected data to an established factor analysis model. DATAN program was applied for determination of acidity constants. Results show that the pKa values of fluorescein are influenced as the percentages of an anionic and a cationic surfactant such as SDS and CTAB, respectively, are added to the solution of this reagent. Also, neutral surfactant such as TX100 only affects pKa1. Effects of surfactant on acidity constants and pure spectrum of each component are also discussed 
653 0 |a Spektrofotometrijsko određivanje  |a Fluorescein  |a Micelarni medij  |a Surfaktanti 
700 1 |a Yazdanipour, Ateesa 
700 1 |a Ghasemi, Jahanbakhsh 
700 1 |a Kubista, Mikael 
700 1 |a Sheyda, Azemat 
700 1 |a Alikhah, Mahtab 
773 0 |t Croatica chemica acta  |x 0011-1643  |g 82 (2009), 4 ; str. 753-759  |w nsk.(HR-ZaNSK)000001621 
981 |b B02/09 
998 |a Luko100503  |c vol2o130307 
856 4 2 |u http://hrcak.srce.hr/cca  |y Croatica Chemica Acta